RETIRED ›
This product is no longer available. Some accessories, replacement parts, or services may still be available.
CMA6-L Kipp & Zonen Albedometer (First Class)
Services Available

Overview

The CMA6 complies with the second highest level, First Class, and is constructed around two CMP6 pyranometer sensors. Both sensors are contained in a single housing and have matched sensitivities. The CMA Albedometers are significantly lighter than the previous models due to the completely new design and mounting rod. The reduced weight is important in portable applications such as measurements over snow and ice fields for investigation of global warming effects.

Read More

Images

Detailed Description

The white sun shield prevents the body of the albedometer from heating up. The conical lower glare screen prevents direct illumination of the lower glass dome at sunrise and sunset.

A bubble level is fitted and a screw-in drying cartridge keeps the interior free from humidity. The screw-in drying cartridge is easy to remove and the replacement desiccant is supplied in convenient refill packets. The signal cable has a waterproof connector for ease of installation.

All albedometers are supplied with a calibration certificate traceable to the World Radiation Centre.

Specifications

  • Spectral range: 285 to 2800 nm 
  • Sensitivity: 5 to 20 µV/W/m² 
  • Response time: < 18 s 
  • Zero offset A: < 10 W/m² 
  • Zero offset B: < 5 W/m² 
  • Directional error (up to 80° with 1000 W/m² beam): < 20 W/m² 
  • Temperature dependence of sensitivity (-10 ºC to +40 ºC): < 4 % 
  • Operating temperature: -40 to +80 °C 
  • Maximum solar irradiance: 2000 W/m² 
  • Field of view: 180 °
  • Cable Length: User specified
  • Warranty: 2 years

Compatibility

Datalogger Considerations

Compatible Contemporary Dataloggers

CR200(X) Series CR800/CR850 CR1000 CR3000 CR5000 CR7X CR9000X

Compatible Retired Dataloggers

CR500 CR510 CR10 CR10X 21X CR23X CR9000