The CRS456 consists of a water-level and water-temperature sensor that has its own time clock and memory to store the collected data, in a compact titanium case. This frees users to place the sensor in remote sites and let it collect data for long periods. The sensor can then be retrieved, connected to a PC via a micro-USB port, and the data transferred to the PC. HydroSci software is included and elegantly supports test setup, data retrieval, and data display. Long battery life and rugged construction mean you can trust the CRS456 to collect important data. Low cost and ease of use make it a good choice in a variety of applications. The CRS451 is the same as this, but with a stainless-steel case.
Read MoreThe CRS456 has several pressure range options. The CRS456 is unvented; therefore it is monitoring sealed gage pressure. For maximum accuracy, the data should be corrected for barometric pressure.
HydroSci software is available for download. This software simplifies the process of configuring the CRS456. Users can configure the CRS456 to monitor surface water, ground water, or a standard pump test.
HydroSci software will also compensate the measurements for barometric pressure using an additional CS456 or a CS451 as a reference sensor, or using a barometric pressure sensor from a nearby weather station.
HydroSci software will display the data in tabular or graphical formats.
Venting | Unvented |
Measurement Time | < 1.0 s |
Output Options | micro USB |
Internal Data Collection Memory | 4 MB |
Logging/Scanning Modes | Standard, Delta, Wave, Logarithmic |
Resolution | 0.0035% FS |
Dry Storage Temperature Range |
-10° to +80°C WARNING: Sensor could be damaged if encased in frozen ice. |
Operating Temperature Range |
0° to 60°C WARNING: Sensor could be damaged if encased in frozen ice. |
Overpressure | 2 x pressure range |
Power Requirements | Internal user-replaceable lithium battery |
Battery Life | 5+ years (when logging interval is once per hour) |
Body Material | Titanium |
Distance |
|
Water-Level Accuracy |
±0.1% full-scale-range TEB Includes the combined errors due to nonlinearity, hysteresis, nonrepeatability, and thermal effects over the compensated temperature range, per ISA S51.1. |
Temperature Accuracy | ±0.2°C |
Ingress Protection | Exceeds IP68 |
Diameter | 2.22 cm (0.875 in.) |
Length | 22.23 cm (8.75 in.) |
Weight | 230 g (0.51 lb) |
Power Consumption |
|
Quiescent | < 80 µA |
Measurement/Communication | 4 mA (1 s measurement) |
Measurement Ranges at Fresh Water Depths |
|
0 to 5.1 m (16.7 ft) |
|
0 to 10.2 m (33.4 ft) |
|
0 to 20.4 m (67 ft) |
|
0 to 50.9 m (167 ft) |
|
0 to 102 m (334.5 ft) |
|
Requires a micro USB cable and HydroSci software running on a computer with Windows XP or later. HydroSci software is available for download.
Adds Chinese language support for version 1.2 of HydroSci.
Note: Language support for the above listed version only.
HydroSci is used to configure and extract data from the CRS45X Recording Submersible Pressure Transducer and the OBS-3A Turbidity and Temperature Monitoring System.
Watch the Video Tutorial: Using HydroSci software with water-level recording sensors.
Number of FAQs related to CRS456: 1
The CRS451 and CRS456 are unvented and monitor sealed gage pressure. For maximum accuracy, the data should be corrected for barometric pressure. The barometric pressure data from a nearby weather station or other monitoring platform can be used.