RETIRED ›
This product is no longer available and has been replaced by: NL121. Some accessories, replacement parts, or services may still be available.
NL120 Ethernet Interface
Services Available
Repair Yes
Calibration No
Free Support Yes

Overview

The NL120 allows the data logger to communicate over a local network or a dedicated Internet connection via TCP/IP. This small, rugged communication device connects directly to the 40-pin peripheral port on a CR1000 or CR3000 datalogger.

Read More

Benefits and Features

  • Compatible with CR1000 and CR3000
  • Connects a data logger to a network
  • Smallest Ethernet module available for the CR1000 and CR3000

Images

Detailed Description

The NL120 uses a straight through cable when the cable is run from a hub to the NL120. A 10baseT Ethernet crossover cable is used if the cable is run directly from the computer to the NL120. For cable lengths longer than 9 feet, either a shielded 10baseT Ethernet cable or the 28033 surge protector needs to be used.

The NL120 is set up using the Device Configuration utility (DevConfig). DevConfig is bundled with our PC400, RTDAQ, and LoggerNet software and is available, at no charge, from: www.campbellsci.com/downloads


Specifications

Power Requirements 12 V (supplied through the data logger’s peripheral port)
Ethernet Speed 10Base-T (10 Mbps), half-duplex
Typical Current Drain 20 mA
Dimensions 10.2 x 6.4 x 2.8 cm (4.0 x 2.5 x 1.1 in.)
Weight 66.62 g (2.35 oz)

EMI and ESD Protection

European Standards Meets requirements for a class A device under European Standards.
Application of Council Directive(s) 89/336/EEC as amended by 89/336/EEC and 93/68/EEC
Standards to Which Conformity Is Declared EN55022-1; 1995 and EN50082-1: 1992

Software Requirements

LoggerNet Version 3.2 or later
PC400 Version 1.3 or later
DevConfig Version 1.5 or later

Compatibility

Please note: The following shows notable compatibility information. It is not a comprehensive list of all compatible products.

Data Loggers

Compatible Note
CR1000 (retired)
CR200X (retired)
CR206X (retired)
CR295X (retired)
CR3000 (retired)
CR5000 (retired)
CR800 (retired)
CR850 (retired)
CR9000X (retired)

Mounting Equipment

Compatible Note
ENC10/12
ENC10/12R Attached to a CR1000 or CR3000
ENC12/14 Attached to a CR1000
ENC14/16 Attached to a CR1000 or CR3000
ENC16/18 Attached to a CR1000 or CR3000

Additional Compatibility Information

Ethernet Cable

A 10baseT Ethernet straight through cable is used when the cable is run from a hub to the NL120. A 10baseT Ethernet crossover cable is used if the cable is run directly from the computer to the NL120. For cable length longer than 9 ft, the 10baseT Ethernet cable must be shielded or the 28033 surge suppressor must be used.

Data Logger Considerations

The NL120 fastens onto the data logger's 40-pin peripheral port. This means that the NL120 is only compatible with the CR1000 and CR3000. It is NOT compatible with the CR800, CR850, CR200X, CR5000, or CR9000X dataloggers.

Related Documents

Product Brochures

FAQs for

Number of FAQs related to NL120: 23

Expand AllCollapse All

  1. The NL120 is a communications peripheral only. It does not provide additional analog terminals for a data logger.

  2. Yes. The NL120 operates as transparent.

  3. Yes, the NL120 can be repaired. Refer to the Repair and Calibration page for the process of returning equipment to Campbell Scientific.

  4. There is no separate firmware for the NL120. It is built into the main data logger’s operating system.

  5. The PakBus protocol allows multiple simultaneous connections. The PakBus address that LoggerNet uses for itself on one of the PCs needs to be changed, though.

  6. The following are some possible causes:

    • The data logger’s OS needs to be updated.
    • A fault exists in the communications link away from the data logger.
    • The NL120 is not fully plugged in.
    • There are loose or broken cables.
    • For a radio link, the aerial connections and alignment may need adjusting.
    • The NL120 or another device has suffered lightning damage.