CS615-L Water Content Reflectometer
Services Available
Repair No
Calibration No
Free Support No

Overview

The CS615 Water Content Reflectometer measures the volumetric water content of porous media using time-domain measurement methods. The reflectometer connects directly to the single-ended analog input of a Campbell Scientific CR510, CR10(X), or CR23X, or to the pulse count channel of a CR510, CR10(X), 21X, CR23X, or CR7 datalogger. The data logger period or frequency output can be converted to volumetric water content using calibration values.

Read More

Images

Detailed Description

The CS615 was replaced by the CS616, which offers a faster, less noise emissive measurement that meets CE standards.


Specifications

Accuracy
  • ±3% (typical)
  • ±2% (with soil-specific calibration)
Power 70 mA (@ 12 Vdc)
Rod Spacing 3.2 cm (1.26 in.)
Rod Diameter 3.2 mm (0.126 in.)
Rod Length 30.0 cm (11.81 in.)
Weight 280 g (0.617 lb)

Compatibility

Please note: The following shows notable compatibility information. It is not a comprehensive list of all compatible products.

Data Loggers

Compatible Note
21X (retired)
CR10 (retired)
CR1000 (retired)
CR10X (retired)
CR200X (retired)
CR206X (retired)
CR23X (retired)
CR295X (retired)
CR3000 (retired)
CR500 (retired)
CR5000 (retired)
CR510 (retired)
CR800 (retired)
CR850 (retired)
CR9000 (retired)
CR9000X (retired)