The CS225 is a prime example of our commitment to provide the highest-quality monitoring products in the world. Our revamped design, rigorous validation process, and stringent quality standards are all focused on providing the fantastic quality you require to reliably generate data you can trust, even in the harshest of environments. Learn more about the CS225's quality testing and validation process.
The CS225 temperature string uses multi-point temperature profiles and SDI-12 digital technology for simple integration and reliability. The CS225 consists of an arrangement of temperature sensors mounted in rugged steel-reinforced cable, permitting it to be buried, submerged, or integrated directly into structures. Temperature points are over-molded to provide long-term protection in all mediums. Each CS225 is custom manufactured.
Temperature profiling with the CS225 is suited for a wide variety of applications and environments, including the following:
We know clients need a really tough temperature string. These strings will be pulled through conduit, buried under concrete, frozen underground, and submersed in water, so quality is of the utmost importance. We put the CS225 through various tests to ensure it can withstand bending, pulling, pressure, freeze/thaw cycles, and temperature cycles. This series of tests confirmed the physical and electrical integrity of the CS225.
When power is supplied to the CS225 probe, the internal electronics will continuously measure the temperature at an approximate rate of 1 measurement per second. Every output measurement obtained from the sensor is a running average of 10 consecutive 1-second readings. The accuracy specification is based on an average of 10 consecutive readings. For this purpose, after initial power-up, it is recommended to delay 10 seconds to obtain the best accuracy.
Because the sensor is obtaining a measurement every 1 second, it is recommended to use the Continuous measurement command to obtain the temperature readings. Using the “R” commands will reduce the time taken to obtain a reading with the SDI-12 protocol.
Operating Temperature Range | -55° to +85°C |
Typical Accuracy | ±0.2°C (-40° to +85°C) includes lifetime drift |
Worst Case Accuracy |
|
Resolution | 0.0078°C |
Maximum Pressure | 150 psi |
Communications | SDI-12 |
Maximum Sensors per Probe | 36 |
Minimum Spacing | 15 cm (5.91 in.) |
Supply Voltage | 9 to 28 Vdc |
Current Consumption |
|
Warm-up Time on Power up | 10 s |
Temperature Point Diameter | 2.22 cm (0.875 in.) |
Maximum Cable Length | 152 m (500 ft) |
User-resettable min/max temperature recording | Yes |
Min/max temperature recording duration | Lifetime |
Automatic temperature update interval | 1 s |
Please note: The following shows notable compatibility information. It is not a comprehensive list of all compatible products.
Compatible | Note | |
---|---|---|
CR1000 (retired) | ||
CR200X (retired) | ||
CR206X (retired) | ||
CR295X (retired) | ||
CR300 | ||
CR3000 (retired) | ||
CR350 | ||
CR500 (retired) | ||
CR6 | ||
CR800 (retired) | ||
CR850 (retired) | ||
CR9000 (retired) |
Our handy CS225 Configuration Tool can help you configure your string, and it assists our staff with customizing your string to your specifications. It includes parameters for lead length, first sensor from ground, and distance between sensors.