CS230 SDI-12 Temperature Profiler
Customizable
Rugged, digital temperature measurements
weather applications supported water applications supported energy applications supported gas flux and turbulence applications supported infrastructure applications supported soil applications supported

Overview

The CS230 temperature profiler uses SDI-12 digital technology for simple integration. SDI-12 does away with analog measurement inaccuracies and susceptibility to electrical noise. The CS230 consists of a rigid probe assembly and up to four optional external temperature probes. The rigid probe assembly maintains the precise position of the temperature points within the profile, while protecting the temperature sensors in all mediums for the long-term.

The CS230 is suited for a wide variety of applications and environments. The completely sealed probe assembly and external probes permit the CS230 to be used in roadbeds, soils, and water (snow and ice). Applications where the CS230 is used include spring-load adjustment, frost and permafrost monitoring, and soil  and water temperature profiling.

Read More

Images


Compatibility

Please note: The following shows notable compatibility information. It is not a comprehensive list of all compatible products.

Data Loggers

Compatible Note
CR1000 (retired)
CR200X (retired)
CR206X (retired)
CR295X (retired)
CR300 (retired)
CR3000 (retired)
CR350
CR500 (retired)
CR6
CR800 (retired)
CR850 (retired)
CR9000 (retired)

Additional Compatibility Information

Configuration

Our handy CS230 Configuration Tool can help you configure your profiler, and it assists our staff with customizing your profiler to your specifications. It includes parameters for lead length, first sensor from ground, and distance between sensors.

CS230 Configurator Tool

Specifications

Operating Temperature Range -55° to +85°C
Typical Accuracy ±0.2°C (-40° to +85°C) includes lifetime drift
Worst Case Accuracy
  • ±0.4°C (−40° to +85°C) includes lifetime drift
  • ±0.5°C (-55° to -40°C) includes lifetime drift
Resolution 0.0078°C
Communications SDI-12
Maximum Sensors per Probe 32
Minimum Spacing 5 cm (1.97 in.)
Optional External Probes 4 (maximum)
Supply Voltage 9 to 28 Vdc
Current Consumption
  • 1.0 mA (max) quiescent current draw per sensor
  • 20 mA + (# sensors * 1.0 mA) active current draw
Warm-up Time on Power up 10 s
Probe Diameter 2.13 cm (0.84 in.)
Standard External Probe Length 45 cm (18 in.)
Maximum Length 3.0 m (118 in.)
Maximum Cable Length 152 m (500 ft)